Status | supported |
---|---|
Source code | hantek-6xxx |
Channels | 2 |
Samplerate | 48MHz |
Analog bandwidth | 20MHz |
Vertical resolution | 8bit |
Triggers | none (SW-only) |
Input impedance | 1MΩ‖25pF |
Memory | none |
Display | none |
Connectivity | USB |
Website | hantek.com |
|
|
S2 | S1 | S0 | 74HC4051D Mux | VDIVs (vendor software) |
---|---|---|---|---|
0 | 0 | 0 | Y0 to Z | 200mV |
0 | 0 | 1 | Y1 to Z | 500mV |
0 | 1 | 0 | Y2 to Z | 5V, 2V, 1V |
0 | 1 | 1 | Y3 to Z | 100mV, 50mV, 20mV |
(Low, but not GND) A0 | 1- | O | -8 | VCC |
(GND) A1 | 2- | -7 | WP (GND) | |
(GND) A2 | 3- | -6 | SCL (FX2 SCL) | |
VSS | 4- | -5 | SDA (FX2 SDA) |
AD9288 pins | Description |
---|---|
S1, S2 | S1=VCC, S2=GND. 'Normal operation, data align disabled'. |
DFS | Tied to GND. Data format select = 'offset binary' (not 'twos complement'). |
AINA, AINB | Analog input channels. |
FX2 pins | Description | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CTL2 | Connected to AD9288 ENCA and ENCB and FX2 IFCLK. | |||||||||||||||
PB0-PB7 | Connected to AD9288 D0A-D7A. | |||||||||||||||
PD0-PD7 | Connected to AD9288 D0B-D7B. | |||||||||||||||
PA7 | 1kHz probe calibration pin. | |||||||||||||||
PC0/PC1 | Dual-color (red/green) LED.
|
Oscilloscope command | bRequest value | Notes |
---|---|---|
Set CH0 voltage range | 0xE0 | Possible values: 1, 2, 5, 10 (5V, 2.5V, 1V, 500mV). |
Set CH1 voltage range | 0xE1 | Possible values: 1, 2, 5, 10 (5V, 2.5V, 1V, 500mV). |
Set sampling rate | 0xE2 | Possible values: 48, 30, 24, 16, 8, 4, 1 (MHz) and 50, 20, 10 (*10kHz). |
Trigger oscilloscope | 0xE3 | Possible values: 1 start sampling. 0 ignored currently. |
Set number of channels | 0xE4 | Possible values: 1, 2. |